075316 - ČSN EN 15502-2-1+A1 - Kotle na plynná paliva pro ústřední vytápění - Část 2-1: Zvláštní norma pro kotle provedení C a kotle provedení B2, B3 a B5, se jmenovitým tepelným příkonem nejvýše 1 000 kW | ||
Název : 075316 - ČSN EN 15502-2-1+A1 - Kotle na plynná paliva pro ústřední vytápění - Část 2-1: Zvláštní norma pro kotle provedení C a kotle provedení B2, B3 a B5, se jmenovitým tepelným příkonem nejvýše 1 000 kW
Označení normy : ČSN EN 15502-2-1+A1 Katalogové číslo : 519134 Třídící znak : 075316 Účinnost : 2024-08-01 Věstník : 2024.07 Strany : 108 Převzata :vyhlášením ve Věstníku - v angličtině | ||
Cena : | 701.00 Kč (DPH= 0%), s DPH= 701.00 Kč | |
ANOTACE "ČSN EN 15502-2-1+A1 This European Standard specifies, the requirements and test methods concerning, in particular, the construction, safety, fitness for purpose, and rational use of energy, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as "boilers". Where the word boiler is used, it needs to be read as the boiler including its connecting ducts, ducts and terminals, if any. !This European Standard covers gas-fired central heating boilers from the types C1 up to C9 and the types B2, B3 and B5: NOTE - For further background information on appliance types see CEN/TR 1749:2014." a) that have a nominal heat input (on the basis of net calorific value) not exceeding 1 000 kW; b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437; c) where the temperature of the heat transfer fluid does not exceed 105 st.C during normal operation; d) where the maximum operating pressure in the water circuit does not exceed 6 bar; e) which may or may not give rise to condensation under certain circumstances; f) which are declared in the installation instructions to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler"; if no declaration is given the boiler is to be considered a "standard boiler"; g) which are intended to be installed either indoors or outdoors in a partially protected place; h) which may include the facility to produce hot water, either by the instantaneous or storage principle, the whole being marketed as a single unit; i) which are designed for either sealed water systems or for open water systems; j) which are either modular boilers, or non- modular boilers. !This European Standard also covers gas-fired condensing central heating boilers from the types C(10) that are equipped with a gas-air ratio control and that have a pmax, saf(min) of 25 Pa, and C(11) boilers that have condensing boiler modules that are equipped with a gas-air ratio control and that have a pmax, saf(min) of 25 Pa." This European Standard provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard, the risk associated with this alternative construction needs to be assessed. An example of an assessment methodology, based upon risk assessment and which covers the essential requirements of the Gas Appliance Directive, is given in Clause 11. EN 15502-2-1:2012+A1:2016 (E) 11 This European Standard does not cover all the requirements for: ! k) Appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex XC);" l) Appliances using flue dampers; ! m) Appliances of the types B21, B31, B51, C21, C41, C51, C61, C71, C81 ,C(12) and C(13);" n) C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW; o) Appliances incorporating flexible plastic flue liners; ! p) C(10) boilers: 1) without a gas-air ratio control, or 2) which are non-condensing appliances, or 3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (?pmax, saf(min)); q) C(11) boilers that have boiler modules: 1) without a gas-air ratio control, or 2) which are non-condensing appliances, or 3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (pmax, saf(min));" r) Appliances intended to be connected to a (common) flue having mechanical extraction." |